Bộ nguồn QUINT-PS/1AC/24DC/40 2866789
Thông số kỹ thuật Phoenix contact QUINT-PS/1AC/24DC/40
2320924 Bộ nguồn QUINT-PS/3AC/24DC/20/CO
2320898 Bộ nguồn QUINT-PS/1AC/24DC/20/CO
2866802 Bộ nguồn QUINT-PS/3AC/24DC/40
2320908 Bộ nguồn QUINT-PS/1AC/24DC/5/CO
2320911 Bộ nguồn QUINT-PS/1AC/24DC/10/CO
2866679 Bộ nguồn QUINT-PS/1AC/48DC/5
2866682 Bộ nguồn QUINT-PS/1AC/48DC/10
2866789 Bộ nguồn QUINT-PS/1AC/24DC/40
2866776 Bộ nguồn QUINT-PS/1AC/24DC/20
2866763 Bộ nguồn QUINT-PS/1AC/24DC/10
2866747 Bộ nguồn QUINT-PS/1AC/24DC/3.5
2866705 Bộ nguồn QUINT-PS/3AC/24DC/10
2866792 Bộ nguồn QUINT-PS/3AC/24DC/20
2866734 Bộ nguồn QUINT-PS/3AC/24DC/5
Dimensions
| Width | 180 mm |
|---|---|
| Height | 130 mm |
| Depth | 125 mm |
| Width with alternative assembly | 122 mm |
| Height with alternative assembly | 130 mm |
| Depth with alternative assembly | 183 mm |
Ambient conditions
| Degree of protection | IP20 |
|---|---|
| Ambient temperature (operation) | -25 °C … 70 °C (> 60 °C Derating: 2.5 %/K) |
| Ambient temperature (start-up type tested) | -40 °C |
| Ambient temperature (storage/transport) | -40 °C … 85 °C |
| Max. permissible relative humidity (operation) | ≤ 95 % (at 25 °C, non-condensing) |
| Climatic class | 3K3 (in acc. with EN 60721) |
| Degree of pollution | 2 |
| Installation height | 4000 m |
Input data
| Nominal input voltage range | 100 V AC … 240 V AC |
|---|---|
| 120 V DC … 300 V DC (UL 508: ≤ 250 V DC) | |
| Input voltage range | 85 V AC … 264 V AC |
| 90 V DC … 300 V DC (UL 508: ≤ 250 V DC) | |
| Dielectric strength maximum | 300 V AC |
| AC frequency range | 45 Hz … 65 Hz |
| Frequency range DC | 0 Hz |
| Discharge current to PE | < 3.5 mA |
| Current consumption | 8.8 A (120 V AC) |
| 4.6 A (230 V AC) | |
| 9.5 A (110 V DC) | |
| 4.7 A (220 V DC) | |
| Nominal power consumption | 1157 VA |
| Inrush surge current | < 15 A (typical) |
| Mains buffering | > 35 ms (120 V AC) |
| > 35 ms (230 V AC) | |
| Input fuse | 20 A (slow-blow, internal) |
| Choice of suitable circuit breakers | 16 A … 20 A (AC: Characteristics B, C, D, K) |
| Type of protection | Transient surge protection |
| Protective circuit/component | Varistor, gas-filled surge arrester |
đại lý QUINT-PS/1AC/24DC/40 | nhà phân phối QUINT-PS/1AC/24DC/40 2866789
| Nominal output voltage | 24 V DC ±1 % |
|---|---|
| Setting range of the output voltage (USet) | 18 V DC … 29.5 V DC (> 24 V DC, constant capacity restricted) |
| Nominal output current (IN) | 40 A (-25 °C … 60 °C, UOUT = 24 V DC) |
| POWER BOOST (IBoost) | 45 A (-25°C … 40°C permanent, UOUT = 24 V DC ) |
| Selective Fuse Breaking (ISFB) | 215 A (12 ms) |
| Derating | 60 °C … 70 °C (2.5%/K) |
| Connection in parallel | Yes, for redundancy and increased capacity |
| Connection in series | yes |
| Feedback resistance | max. 35 V DC |
| Protection against surge voltage on the output | < 35 V DC |
| Residual ripple | < 30 mVPP (with nominal values) |
| Output power | 960 W |
| Typical response time | < 0.7 s |
| Maximum power dissipation in no-load condition | 14 W |
| Power loss nominal load max. | 80 W |
| Net weight | 3.3 kg |
|---|---|
| Efficiency | > 92 % (for 230 V AC and nominal values) |
| Insulation voltage input/output | 4 kV AC (type test) |
| 2 kV AC (routine test) | |
| Insulation voltage input / PE | 3.5 kV AC (type test) |
| 2 kV AC (routine test) | |
| Insulation voltage output / PE | 500 V DC (routine test) |
| Protection class | I |
| Degree of protection | IP20 |
| MTBF (IEC 61709, SN 29500) | > 900000 h (25 °C) |
| > 530000 h (40 °C) | |
| Mounting position | horizontal DIN rail NS 35, EN 60715 |
| Assembly instructions | alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom |
| Connection method | Screw connection |
|---|---|
| Conductor cross section solid min. | 0.2 mm² |
| Conductor cross section solid max. | 6 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 4 mm² |
| Conductor cross section AWG min. | 14 |
| Conductor cross section AWG max. | 10 |
| Stripping length | 7 mm |
| Screw thread | M3 |
| Connection method | Screw connection |
|---|---|
| Conductor cross section solid min. | 0.5 mm² |
| Conductor cross section solid max. | 16 mm² |
| Conductor cross section flexible min. | 0.5 mm² |
| Conductor cross section flexible max. | 16 mm² |
| Conductor cross section AWG min. | 8 |
| Conductor cross section AWG max. | 6 |
| Stripping length | 10 mm |
| Screw thread | M4 |
| Conductor cross section solid min. | 0.2 mm² |
|---|---|
| Conductor cross section solid max. | 6 mm² |
| Conductor cross section flexible min. | 0.2 mm² |
| Conductor cross section flexible max. | 4 mm² |
| Conductor cross section AWG min. | 24 |
| Conductor cross section AWG max. | 10 |
| Screw thread | M3 |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
|---|---|
| Noise emission | EN 55011 (EN 55022) |
| Noise immunity | EN 61000-6-2:2005 |
| Connection in acc. with standard | CSA |
| Standards/regulations | EN 61000-4-2 |
| Contact discharge | 4 kV (Test Level 2) |
| Standards/regulations | EN 61000-4-3 |
| Frequency range | 80 MHz … 1 GHz |
| Test field strength | 10 V/m (Test Level 3) |
| Frequency range | 1.4 GHz … 2 GHz |
| Test field strength | 3 V/m (Test Level 2) |
| Standards/regulations | EN 61000-4-4 |
| Comments | Criterion B |
| Standards/regulations | EN 61000-6-3 |
| EN 61000-4-6 | |
| Frequency range | 0.15 MHz … 80 MHz |
| Voltage | 10 V (Test Level 3) |
| Low Voltage Directive | Conformance with LV directive 2006/95/EC |
| Standard – Electrical safety | IEC 60950-1/VDE 0805 (SELV) |
| Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations | EN 50178/VDE 0160 (PELV) |
| Standard – Safety extra-low voltage | IEC 60950-1 (SELV) and EN 60204-1 (PELV) |
| Standard – Safe isolation | DIN VDE 0100-410 |
| DIN VDE 0106-101 | |
| Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment | EN 50178 |
| Standard – Limitation of mains harmonic currents | EN 61000-3-2 |
| Standard – Equipment safety | BG (design tested) |
| Standard – Approval for medical use | IEC 60601-1, 2 x MOOP |
| Shipbuilding approval | DNV GL (EMC A), ABS, LR, RINA, NK, BV |
| UL approvals | UL Listed UL 508 |
| UL/C-UL Recognized UL 60950-1 | |
| UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) | |
| Shock | 18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
| Vibration (operation) | < 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
| 15 Hz … 150 Hz, 2.3g, 90 min. | |
| Information technology equipment – safety (CB scheme) | CB Scheme |
| Rail applications | EN 50121-4 |
| Overvoltage category (EN 62477-1) | III |
Bài viết liên quan
- Bộ sưởi Rittal
- Bộ nguồn EA Elektro Automatik EA PS 824 20SM
- Bộ thu phát tín hiệu MOXA AWK-3131
- Bộ nguồn DPSN-400BB
- Cảm biến chốt cắt cánh hướng JX-25
- Đại lý phân phối Faster
Xem thêm toàn bộ sản phẩm tự động hoá hoặc quay lại trang chủ ONTIDA.
Câu hỏi thường gặp
Bộ nguồn QUINT-PS/1AC/24DC/40 2866789 là gì?
Bộ nguồn QUINT-PS/1AC/24DC/40 2866789 là nội dung kỹ thuật do ONTIDA biên soạn, tổng hợp thông tin về thiết bị, thông số và ứng dụng trong hệ thống tự động hoá công nghiệp.
Bộ nguồn QUINT-PS/1AC/24DC/40 2866789 còn hàng không và giao trong bao lâu?
Tình trạng hàng thay đổi theo từng thời điểm. Mã có sẵn giao trong 1–2 ngày làm việc, mã phải đặt theo lịch nhập khẩu cần nhiều thời gian hơn — vui lòng liên hệ để được xác nhận.
Giá của thiết bị nêu trong bài được tính thế nào?
Giá phụ thuộc số lượng, thời gian giao và tình trạng tồn kho nên không niêm yết cố định. Vui lòng liên hệ để nhận báo giá theo nhu cầu thực tế.
Có model nào thay thế được không?
Nhiều mã trong cùng dòng sản phẩm có thể thay thế cho nhau nếu trùng thông số điện và cơ khí. ONTIDA hỗ trợ đối chiếu tài liệu kỹ thuật trước khi đề xuất model tương đương.