Thông số kỹ thuật Phoenix contact QUINT-PS/1AC/24DC/40
2320924 Bộ nguồn QUINT-PS/3AC/24DC/20/CO
2320898 Bộ nguồn QUINT-PS/1AC/24DC/20/CO
2866802 Bộ nguồn QUINT-PS/3AC/24DC/40
2320908 Bộ nguồn QUINT-PS/1AC/24DC/5/CO
2320911 Bộ nguồn QUINT-PS/1AC/24DC/10/CO
2866679 Bộ nguồn QUINT-PS/1AC/48DC/5
2866682 Bộ nguồn QUINT-PS/1AC/48DC/10
2866789 Bộ nguồn QUINT-PS/1AC/24DC/40
2866776 Bộ nguồn QUINT-PS/1AC/24DC/20
2866763 Bộ nguồn QUINT-PS/1AC/24DC/10
2866747 Bộ nguồn QUINT-PS/1AC/24DC/3.5
2866705 Bộ nguồn QUINT-PS/3AC/24DC/10
2866792 Bộ nguồn QUINT-PS/3AC/24DC/20
2866734 Bộ nguồn QUINT-PS/3AC/24DC/5
Dimensions
Width |
180 mm |
Height |
130 mm |
Depth |
125 mm |
Width with alternative assembly |
122 mm |
Height with alternative assembly |
130 mm |
Depth with alternative assembly |
183 mm |
Back to top
Ambient conditions
Degree of protection |
IP20 |
Ambient temperature (operation) |
-25 °C … 70 °C (> 60 °C Derating: 2.5 %/K) |
Ambient temperature (start-up type tested) |
-40 °C |
Ambient temperature (storage/transport) |
-40 °C … 85 °C |
Max. permissible relative humidity (operation) |
≤ 95 % (at 25 °C, non-condensing) |
Climatic class |
3K3 (in acc. with EN 60721) |
Degree of pollution |
2 |
Installation height |
4000 m |
Input data
Nominal input voltage range |
100 V AC … 240 V AC |
|
120 V DC … 300 V DC (UL 508: ≤ 250 V DC) |
Input voltage range |
85 V AC … 264 V AC |
|
90 V DC … 300 V DC (UL 508: ≤ 250 V DC) |
Dielectric strength maximum |
300 V AC |
AC frequency range |
45 Hz … 65 Hz |
Frequency range DC |
0 Hz |
Discharge current to PE |
< 3.5 mA |
Current consumption |
8.8 A (120 V AC) |
|
4.6 A (230 V AC) |
|
9.5 A (110 V DC) |
|
4.7 A (220 V DC) |
Nominal power consumption |
1157 VA |
Inrush surge current |
< 15 A (typical) |
Mains buffering |
> 35 ms (120 V AC) |
|
> 35 ms (230 V AC) |
Input fuse |
20 A (slow-blow, internal) |
Choice of suitable circuit breakers |
16 A … 20 A (AC: Characteristics B, C, D, K) |
Type of protection |
Transient surge protection |
Protective circuit/component |
Varistor, gas-filled surge arrester |
đại lý QUINT-PS/1AC/24DC/40 | nhà phân phối QUINT-PS/1AC/24DC/40 2866789
Nominal output voltage |
24 V DC ±1 % |
Setting range of the output voltage (USet) |
18 V DC … 29.5 V DC (> 24 V DC, constant capacity restricted) |
Nominal output current (IN) |
40 A (-25 °C … 60 °C, UOUT = 24 V DC) |
POWER BOOST (IBoost) |
45 A (-25°C … 40°C permanent, UOUT = 24 V DC ) |
Selective Fuse Breaking (ISFB) |
215 A (12 ms) |
Derating |
60 °C … 70 °C (2.5%/K) |
Connection in parallel |
Yes, for redundancy and increased capacity |
Connection in series |
yes |
Feedback resistance |
max. 35 V DC |
Protection against surge voltage on the output |
< 35 V DC |
Residual ripple |
< 30 mVPP (with nominal values) |
Output power |
960 W |
Typical response time |
< 0.7 s |
Maximum power dissipation in no-load condition |
14 W |
Power loss nominal load max. |
80 W |
Net weight |
3.3 kg |
Efficiency |
> 92 % (for 230 V AC and nominal values) |
Insulation voltage input/output |
4 kV AC (type test) |
|
2 kV AC (routine test) |
Insulation voltage input / PE |
3.5 kV AC (type test) |
|
2 kV AC (routine test) |
Insulation voltage output / PE |
500 V DC (routine test) |
Protection class |
I |
Degree of protection |
IP20 |
MTBF (IEC 61709, SN 29500) |
> 900000 h (25 °C) |
|
> 530000 h (40 °C) |
|
|
Mounting position |
horizontal DIN rail NS 35, EN 60715 |
Assembly instructions |
alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically
alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom |
Connection method |
Screw connection |
Conductor cross section solid min. |
0.2 mm² |
Conductor cross section solid max. |
6 mm² |
Conductor cross section flexible min. |
0.2 mm² |
Conductor cross section flexible max. |
4 mm² |
Conductor cross section AWG min. |
14 |
Conductor cross section AWG max. |
10 |
Stripping length |
7 mm |
Screw thread |
M3 |
Connection method |
Screw connection |
Conductor cross section solid min. |
0.5 mm² |
Conductor cross section solid max. |
16 mm² |
Conductor cross section flexible min. |
0.5 mm² |
Conductor cross section flexible max. |
16 mm² |
Conductor cross section AWG min. |
8 |
Conductor cross section AWG max. |
6 |
Stripping length |
10 mm |
Screw thread |
M4 |
Conductor cross section solid min. |
0.2 mm² |
Conductor cross section solid max. |
6 mm² |
Conductor cross section flexible min. |
0.2 mm² |
Conductor cross section flexible max. |
4 mm² |
Conductor cross section AWG min. |
24 |
Conductor cross section AWG max. |
10 |
Screw thread |
M3 |
Electromagnetic compatibility |
Conformance with EMC Directive 2014/30/EU |
Noise emission |
EN 55011 (EN 55022) |
Noise immunity |
EN 61000-6-2:2005 |
Connection in acc. with standard |
CSA |
Standards/regulations |
EN 61000-4-2 |
Contact discharge |
4 kV (Test Level 2) |
Standards/regulations |
EN 61000-4-3 |
Frequency range |
80 MHz … 1 GHz |
Test field strength |
10 V/m (Test Level 3) |
Frequency range |
1.4 GHz … 2 GHz |
Test field strength |
3 V/m (Test Level 2) |
Standards/regulations |
EN 61000-4-4 |
Comments |
Criterion B |
Standards/regulations |
EN 61000-6-3 |
|
EN 61000-4-6 |
Frequency range |
0.15 MHz … 80 MHz |
Voltage |
10 V (Test Level 3) |
Low Voltage Directive |
Conformance with LV directive 2006/95/EC |
Standard – Electrical safety |
IEC 60950-1/VDE 0805 (SELV) |
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations |
EN 50178/VDE 0160 (PELV) |
Standard – Safety extra-low voltage |
IEC 60950-1 (SELV) and EN 60204-1 (PELV) |
Standard – Safe isolation |
DIN VDE 0100-410 |
|
DIN VDE 0106-101 |
Standard – Protection against shock currents, basic requirements for protective separation in electrical equipment |
EN 50178 |
Standard – Limitation of mains harmonic currents |
EN 61000-3-2 |
Standard – Equipment safety |
BG (design tested) |
Standard – Approval for medical use |
IEC 60601-1, 2 x MOOP |
Shipbuilding approval |
DNV GL (EMC A), ABS, LR, RINA, NK, BV |
UL approvals |
UL Listed UL 508 |
|
UL/C-UL Recognized UL 60950-1 |
|
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location) |
Shock |
18 ms, 30g, in each space direction (according to IEC 60068-2-27) |
Vibration (operation) |
< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
|
15 Hz … 150 Hz, 2.3g, 90 min. |
Information technology equipment – safety (CB scheme) |
CB Scheme |
Rail applications |
EN 50121-4 |
Overvoltage category (EN 62477-1) |
III |