Mô tả ngắn gọn
| I/O module | 2 analog outputs 4 to 20 mA, 0 to 20 mA or 0 to 24 mA |
Thông tin chung
| B&R ID code | 0xE211 |
| Chỉ số trạng thái | I/O function per channel, trạng thái hoạt động, module status, HART |
| Chẩn đoán | |
| Chạy mô-đun/lỗi | Yes, using LED status indicator and software |
| Đầu ra | Yes, using LED status indicator and software |
| HART link | Yes, using LED status indicator and software |
| HART error | Yes, using LED status indicator and software |
| Tiêu thụ điện năng | |
| Bus | 0.05 W |
| Internal I/O | 1.65 W |
| Tiêu tán công suất bổ sung do bộ truyền động gây ra (resistive) [W] | – |
| Chứng nhận | |
| CE | Yes |
| UKCA | Yes |
| ATEX |
Zone 2, II 3G Ex nA nC IIA T5 Gc IP20, Ta (see X20 user’s manual) FTZÚ 09 ATEX 0083X |
| UL |
cULus E115267 Thiết bị điều khiển công nghiệp |
| HazLoc |
cCSAus 244665 Process control equipment for hazardous locations Class I, Division 2, Groups ABCD, T5 |
| DNV |
Nhiệt độ: B (0 to 55°C) Humidity: B (up to 100%) Vibration: B (4 g) EMC: B (bridge and open deck) |
| LR | ENV1 |
| KR | Yes |
| ABS | Yes |
| BV | EC33B Nhiệt độ: 5 – 55°C Vibration: 4 g EMC: Bridge and open deck |
Analog outputs
| Output | 4 to 20 mA, 0 to 20 mA or 0 to 24 mA configurable using software |
| Độ phân giải chuyển đổi kỹ thuật số | 16-bit |
| Settling time on output change over entire range | 2 ms to 20 s, configurable using software |
| Data output rate | |
| With HART | 210 ms (default) |
| Analog | 1 ms without ramp |
| Max. error | |
| Gain | |
| 4 to 20 mA | ±0.025% |
| 0 to 20 mA | ±0.022% |
| 0 to 24 mA | ±0.02% |
| Offset | |
| 4 to 20 mA | ±0.025% |
| 0 to 20 mA | ±0.022% |
| 0 to 24 mA | ±0.02% |
| Bảo vệ đầu ra | Chống đoản mạch, overvoltage protection (up to 30 VDC) |
| Open-circuit detection | Yes, using hardware and software |
| Định dạng dữ liệu | INT |
| Định dạng đầu ra | |
| 4 to 20 mA | INT 0x0000 to 0x7FFF / 1 LSB = 0x0001 = 488.281 nA |
| 0 to 20 mA |
INT 0x0000 to 0x7FFF / 1 LSB = 0x0001 = 610.352 nA UINT 0x0000 to 0xFFFF / 1 LSB = 0x0001 = 305.176 nA |
| 0 to 24 mA | INT 0x0000 to 0x5DC0 / 1 LSB = 0x0001 = 1000 nA |
| Tải per channel | Max. 600 Ω |
| Chống đoản mạch | Yes, continuous |
| Output filter |
Active second-order low-pass filter / Cutoff frequency 19 Hz Configurable slew rate |
| Max. gain drift | |
| 4 to 20 mA | ±0.0055%/°C |
| 0 to 20 mA | ±0.005%/°C |
| 0 to 24 mA | ±0.005%/°C |
| Max. offset drift | |
| 4 to 20 mA | ±0.0035%/°C |
| 0 to 20 mA | ±0.002%/°C |
| 0 to 24 mA | ±0.002%/°C |
| Error caused by load change | |
| 4 to 20 mA | 0.14% |
| 0 to 20 mA | 0.1% |
| 0 to 24 mA | 0.1% |
| Nonlinearity | <0.003% |
| Test voltage | |
| Channel – Channel | 1000 VAC |
| Channel – Bus | 1000 VAC |
| Channel – Ground | 1000 VAC |
HART
| Tỷ lệ chuyển nhượng | 1200 bit/s |
| Operating frequencies | 1200 Hz / 2200 Hz |
| Burst operation possible | Yes |
| Multi-drop operation | |
| Possible | Yes |
| Stations | Up to 15 |
| Transmission amplitude | |
| Minimum | 400 mVpp |
| Typical | 500 mVpp |
| Maximum | 600 mVpp |
| Receiving amplitude | |
| Minimum | 120 mVpp |
| Maximum | 1500 mVpp |
Tính chất điện
| Cách ly điện | Channel isolated from channel and bus |
Điều kiện hoạt động
| Hướng lắp đặt | |
| Nằm ngang | Yes |
| Thẳng đứng | Yes |
| Độ cao lắp đặt so với mực nước biển | |
| 0 to 2000 m | Không có giới hạn |
| >2000 m | Reduction of ambient temperature by 0.5°C per 100 m |
| Mức độ bảo vệ mỗi EN 60529 | IP20 |
Điều kiện môi trường xung quanh
| Nhiệt độ | |
| Hoạt động | |
| Nằm ngang mounting orientation | -25 to 60°C |
| Thẳng đứng mounting orientation | -25 to 50°C |
| Giảm tải | See section “Giảm tải”. |
| Lưu trữ | -40 to 85°C |
| Transport | -40 to 85°C |
| Độ ẩm tương đối | |
| Hoạt động | Up to 100%, condensing |
| Lưu trữ | 5 to 95%, non-condensing |
| Transport | 5 to 95%, non-condensing |
Tính chất cơ học
| Note |
Order 1x cầu đấu X20TB12 separately. Order 1x bus module X20cBM11 separately. |
| Pitch | 12.5+0.2 mm |